How to fit a domed sapphire crystal (Seiko 6309-7040)


Having seen a number of questions regarding the fitting of new crystals to Seiko divers, I have prepared the following simple guide. From the outset I would like to say that anyone can do this, with a few simple tools, even if their 9-year old son William is watching and has an inexhaustible line of questions.


Start with a clean work area. A sheet of printer paper gives a nice, dust-free work surface. The crystal is a domed sapphire crystal from Harold Ng (Yobokies), the watch is a wonderfully patinaed original vintage Seiko 6309 on a Super Oyster with Yobokies solid end links:



Using a sharp pocketknife, ease the bezel off by pushing the knife under the crystal and twisting gently. The bezel will pop off. Take care not to lose the small steel ratcheting ball.



Tell William to keep quiet. Use a rubber-ball (or other) caseback remover to...remove the caseback:



Press down on the retaining mechanism and remove the crown:



Turn the watch over and gently tip out the movement. Cover the movement with a shot glass:



Get another shot glass, pour a whiskey and tell William to keep quiet. Rummage in your box of tools and find the crystal press:



Remove the crystal retaining ring in the same way you removed the bezel:



Send William out to blow his nose. Crystal retaining ring removed:



Use crystal press to remove crystal. A firm squeeze:



...and it pops right out. Check the condition and orientation of the crystal gasket and wipe it with a smear of silicone grease:



Clean the surrounding area with a Q-tip:



Press the new crystal in with the crystal press, checking that the crystal gasket is not pinched:



Place the crystal retaining ring in position:



...and use the crystal press to snap it home:



Insert the movement and crown, making sure the chapter ring lines up:



Lubricate the caseback with a dab of silicone grease and fit, after which the bezel can be snapped on using the crystal press:



And admire your handiwork, after unlocking the cupboard and letting William out:





Time taken: a little over 10 minutes.

THE VERDICT: it was a pleasure to deal with Yobokies, in the same way it is a pleasure to deal with our other suppliers of Seiko parts. We really need to stop up from time to time and thank our blessings by having suppliers who also are enthusiasts

The crystal is a wonderful upgrade to the flat Seiko original. The gentle dome gives depth to the dial and creates a wonderfull play when moving the watch. The dome gives life to the watch and makes it look like it is under water, even when it is not. The AR coating on the inside of the watch gives fascinating blue reflections (see last picture) and makes the dial easy to read at all angles. The fact that it is a scratch resistant sapphire gives peace of mind in daily use. In all, a "mod" which improves an already perfect watch. SCORE: 10/10.

Saturday, October 22, 2011

1964 Cal 430 to 5722 Second Generation Grand Seiko Chronometer transition

 By way of introduction, these "second generation" Grand Seiko chronometers were preceded by cal. 3180 "first generation Grand Seiko". The 43999 has the caliber 430 (with "tadpole" regulation) and is occasionally termed 43GS, while the 57GS have the otherwise identical 5722A (tadpole) or the 5722B ("rack & pinion" regulation) caliber. Both are very similar to the original cal 3180 of the first GS.  My review of the cal. 430 Chronometer Grand Seiko can be seen at the Seiko and Citzen Watch forum

With respect to their crowns, a rule-of-thumb allowing the quick identification of otherwise essentially identical pieces is that the 43999 has a coarse-knurled crown, similar to that of the cal. 3180 "first generation Grand Seiko":




Source: Stefan Molle, http://mollewatch.webgain.se

while the 5722 has the fine-knurled crown:


Source: http://ninanet.net/watches/others15/Mediums/mseiko5722c01.jpg

Both the 43999 and 5722 version of the second GS have the "W SEIKO" imprint on the crown. What is uncertain is whether there was a transitional period where 43999s had a fine-knurled crown, or whether these crowns where subsequently fitted during repair and maintenance.

The following indications suggest that there was indeed a transition period:

Exhibit 1: Antiquorum's recent auction of an early (1965) 5722 with a coarse-knurled crown:


Source: http://catalog.antiquorum.com/catalog.html?action=load&lotid=159&auctionid=253

Not exactly conclusive, but next we have:

Exhibit 2: 43999 paperwork, and what we must assume is the associated 43999, with fine-knurled crown.






Source: uhm, not sure, but seem to remember it was cached from Rakuten.

and finally,

Exhibit 3: From the "Vintage Seiko GS Chronometer Crown Liner 5722 5719 BOOK" what appears to be a cal.430 (=43999) judging from the short three-cifer caliber number on the movement, apparently a 1964 as far as I can make out from the case back, with a fine-knurled crown:



Source: eBay auction


Accordingly, it can be assumed to be correct to fit the fine-knurled crown (part number 55W31NS) to both the 43999 as well as the 5722 caliber second generation Grand Seiko chronometers, while maintaining originality.




Finally, part number 55W31NS is correct for the following watches:

  1. Grand Seiko Chronometer models 5722, 43999
  2. King Seiko Chronometer models 4400-9990, 4420-9920, 44999


Friday, April 16, 2010

Seiko Tuna 300m 7549-7010 disaster, diagnosis and repair





Happiness is a 7049-7010, Sharm-el-Sheikh, January 2010. Little did we know...


It was a dark and stormy night - I lent my son my Tuna to time a five minute foot bath (his foot), and he unintentionally dropped it on a particularly hard floor. Subsequently it ran intermittently, stopping for a while only to run again an hour later. This carried on for a few days, so I opened her up, checked the battery was seated ok, and it was.




Battery seated, as per spec....the plot thickens


At this stage my immediate reaction was to install a spare 7548 movement I have been saving for a project and send the 7549 module for a service. However, 7549 hands will not fit a 7548 movement, as the 7548 movment was developed on the basis of the 6309 mainplate, canon pinion and hour wheel. I wonder if Seiko originally planned to use the 6309 auto caliber in the Tuna, and switched to quartz during its development? Anyway, I was in a quandry as to whether I should install the 7548 caliber with 6309 hands, or whether I should retain the original caliber, dial and hands.


At that precise moment I received a mail from Ken Setser, who encouraged me to take on the diagnosis of the faulty movement, and provided me with a step by step diagnosis strategy. Ken wrote:Harry,The first thing you want to do is to determine if you have a mechanical or electronic problem. 1. Check the battery2. Check to make sure screws are tight and battery insulator is in place. 3. If everything above checks out then you want to get a small compass and set it on the coil(copper colored). The coil should pulse every second and the hand of the compass should deflect whenever it pulses. If the compass hand moves then the problem is mechanical. If it doesn't then the problem is electronic. 4. You want to determine if the problem is in the coil or the electronic module. If you have a ohm meter you can check for continuity in the coil. My guess that the coil would be the problem if it is an electrical problem. If you can, do step 1-3 and let me know what you find. Ken


Under the microscope I was able to confirm that all connections appeared to be intact, and that the jewels and wheel where sitting correctly.




Jewels and small things seated as they should be.



More of the same. I like microscopes.


The next step was to test the coil. A quick trip to the local tourist store netted a small compass, which I placed directly on the movement.



The compass was placed directly on the movement.


For a particularly fascinating video, please see: http://biocomm.eu/7549repair/5.wmv (Remember popcorn). Say, does anyone know how to embed a video?


OK, so YouTube it is:




Hear the tock-tock in the background? Thats our grandfather clock!


So I proudly answered Ken:


Hi Ken I can confirm that when the watch stops, the compass stops moving (as opposed to the 1-sec pulses of the needle clearly obvious when the watch is running), suggesting that the problem is electronic. The movement tends to restart when I wear the watch, but leaving the watch on a hard surface overnight will leave it in a stable state, ie running overnight if left when running, dead overnight if left when dead. I have tried gently prodding the movement to induce running, without luck. The movement will often start running when I loosen the caseback, but not always - I'm sure this is an important piece of information... Am I correct in assuming that the next phase is to localize the source of the sporadic elctronic breakdown, between and including the battery (tried two new batteries) and the coil, on the circuit block itself? Incidentally, I have a spare 7548 movment - would it help troubleshooting to try to replace the 7549 circuit plate and coil with the entire working 7548 circuit plate and coil block, then with the 7549 plate / 7548 coil and vise versa? Of course, if the 7548 plate and coil are a straight switch (wishfulthinking) the problem would be solved, but I would really like to identify the source of the problem just for the challenge of it... The quest continues - I feel like I am playing a sort of WIS chess here! RegardsHarry


Almost immediately Ken replied:

Harry Great troubleshooting techniques. Here is what I think and what I would do. Since the problem is intermittent, I suspect a loose connedtion somewhere. Could be the battery to circuit; circuit to coil; or internal coil problem. I have attached some tech sheets for the movement so you will have some reference. 1. Check the - battery contact to make sure it is firmly attached to the circuit board. Also make sure it is raised enough to make firm connection to the battery 2. Make sure + battery strap is firmly attached to both sides of the circuit. 3. If you look at the circuit just to the left of the word "Japan" you will see a small cutout. Look in the cutout and you will see two gold colored fingers. These are the connections from the circuit to the coil. Make sure they are touching the coil underneath. The best way to do this is to remove the circuit and turn it over. the tech manual has the steps. 4. After you remove the circuit you can check the resisance of the coil. The resistance doesn't matter so much in your situation, only if it is open. 5. If, after doing steps 1-4 everything is ok then clean all the contact points with a pencil eraser, making sure you remove all bits of eraser when done. Reassemble the watch then try it. 6. Let me know what you find. Ken

So, at this stage I was sitting looking at a 7549 movment with an electronic fault, and beside it I had the 7548 movement I had originally planned to insert as a donor movement.



Left: faulty 7549 movement, right: 7548 movement. The mind boggles.


I then remembered that the 7549 was built around a 6309 mainplate, and it began to dawn on me that the 7548 and 7549 movments had different canon pinions and hour wheels (and thereore different minute and hour hand hole sizes), but the two movments I had before me seemed to have identical circuit blocks and coils! I quickly dug out a spare 7546 caliber movement, and again the circuit block and coil appeared identical!



Left: 7549 circuit block, right: 7548 circuit block. Background: artfully placed technical manual sheet.



Left: 7549 circuit block, right: 7548 circuit block.



Throwing caution to the wind, I replaced the circuit block with a circuit block from a 7546 spares movement.




The FrankenTuna, with culprit coil, and now-spare-7549 circuit block and magnetic shield.



While doing this I noticed the antimagnetic shield plate was missing (!) from the original 7549 movement, so I also scavenged the ditto part from the 7546. This failed to solve the problem, but I remembered that the 7546 movement was dead when I got it (these things happen when you get to my age) so the next step was to transfer the coil block from the 7548 movement and - hey presto - it lives!

The lesson learnt thus far is that 7546, 7548 and 7549 coils, circuit blocks and antimagnetic shield plates are freely and easily interchangeable. Considering that it is relatively easy to source 7546 and 7548 parts movements, this could certainly be useful information for some!

I fitted the now strongly-running movement into the case, snugged down the caseback and now have a caliber 7549 Tuna running a caliber 7548 coil in a caliber 7546 circuit block! This is the beauty of the 6309/6 and the 75xx series - they are so closely related and follow Seikos "Lego block" approach!

This amazing thing in this story, however, is that a professional watch restorer like Ken Setser would take the trouble to contact me, and the time to walk me through an extended diagnosis and repair process. And therein, children, lies the essence of the spirit of our WIS community. Thanks, Ken.

Tuesday, April 6, 2010

How to fit a domed sapphire crystal (Seiko 6309-7040)

Having seen a number of questions regarding the fitting of new crystals to Seiko divers, I have prepared the following simple guide. From the outset I would like to say that anyone can do this, with a few simple tools, even if their 9-year old son William is watching and has an inexhaustible line of questions.

Start with a clean work area. A sheet of printer paper gives a nice, dust-free work surface. The crystal is a domed sapphire crystal from Harold Ng (Yobokies), the watch is a wonderfully patinaed original vintage Seiko 6309 on a Super Oyster with Yobokies solid end links:



Using a sharp pocketknife, ease the bezel off by pushing the knife under the crystal and twisting gently. The bezel will pop off. Take care not to lose the small steel ratcheting ball.



Tell William to keep quiet. Use a rubber-ball (or other) caseback remover to...remove the caseback:



Press down on the retaining mechanism and remove the crown:



Turn the watch over and gently tip out the movement. Cover the movement with a shot glass:



Get another shot glass, pour a whiskey and tell William to keep quiet. Rummage in your box of tools and find the crystal press:



Remove the crystal retaining ring in the same way you removed the bezel:



Send William out to blow his nose. Crystal retaining ring removed:



Use crystal press to remove crystal. A firm squeeze:



...and it pops right out. Check the condition and orientation of the crystal gasket and wipe it with a smear of silicone grease:



Clean the surrounding area with a Q-tip:



Press the new crystal in with the crystal press, checking that the crystal gasket is not pinched:



Place the crystal retaining ring in position:



...and use the crystal press to snap it home:



Insert the movement and crown, making sure the chapter ring lines up:



Lubricate the caseback with a dab of silicone grease and fit, after which the bezel can be snapped on using the crystal press:



And admire your handiwork, after unlocking the cupboard and letting William out:





Time taken: a little over 10 minutes.

THE VERDICT: it was a pleasure to deal with Yobokies, in the same way it is a pleasure to deal with our other suppliers of Seiko parts. We really need to stop from time to time and thank our blessings by having suppliers who also are enthusiasts.

The crystal is a wonderful upgrade to the flat Seiko original. The gentle dome gives depth to the dial and creates a wonderful play when moving the watch. The dome gives life to the watch and makes it look like it is under water, even when it is not. The AR coating on the inside of the watch gives fascinating blue reflections (see last picture) and makes the dial easy to read at all angles. The fact that it is a scratch resistant sapphire gives peace of mind in daily use. In all, a "mod" which improves an already perfect watch. SCORE: 10/10.